[Processing stability, removal of pressurized floating devices, etc.] Improvement of wastewater treatment facility at chicken meat primary processing plant.

Change the existing aeration device in the treatment tank to an Aqua Blaster to enhance processing capacity, allowing treatment to be conducted without the use of a pressurized flotation device.

Due to the increase in wastewater volume associated with the factory expansion, the aeration device of the existing treatment tank was changed to an Aqua Blaster to enhance processing capacity. By installing Aqua Blasters in the adjustment tank and aeration tank, we successfully accepted a load increase of 10-20% without increasing the tank size. Furthermore, it has become possible to carry out treatment without using a pressurized flotation device.

  • Drainage and ventilation equipment
  • Turbid water and muddy water treatment machines
  • Sewerage facilities

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Improvement of wastewater treatment facilities at food complexes for processing stability and reduction of electricity costs.

The removal rate of BOD is 80%, and the removal rate of normal hexane extractable substances is 82%, showing significant improvement! Even after more than 8 and a half years, it maintains a no-maintenance state.

Before the installation of the Aqua Blaster, a large amount of grease scum accumulated in just one day, leading to the formation of oil balls. Hydrogen sulfide was generated to the extent that it corroded surrounding equipment. The oil balls on the water surface and those that sank to the bottom were regularly manually retrieved and disposed of as industrial waste. As a result of installing the Aqua Blaster, the removal rate of BOD improved significantly to 80%, and the removal rate of normal hexane extractable substances improved to 82%. Even after more than eight and a half years, there has been no need for removal or dredging work, and a no-maintenance state has continued. The dramatic improvement in water quality has led to waterfowl visiting the sedimentation tank every year without fail. Below are the results from the installation in 2012 until 2020, covering eight years: - With a six-hour retention time in the adjustment tank, BOD and n-hex were cut by over 80%. - The floating grease and settled sludge that had accumulated in the adjustment tank have not been removed even once in eight years. - Hydrogen sulfide levels, which were at 100 ppm, have been reduced to 0 ppm. - The outlet of Aeration Tank 1 meets Setouchi regulations. - The sludge conversion rate for BOD has been reduced from 35% to 25%. - The sedimentation tank has remained stable, attracting ducks. - Excess sludge has drastically decreased, and the odor from its steam drying is no longer a concern.

  • Drainage and ventilation equipment
  • Turbid water and muddy water treatment machines
  • Sewerage facilities

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration